Furnace vent pipe installation code gas furnace venting codes furnace exhaust pipe code furnace flue vent code gas furnace exhaust pipe regulations.
Furnace flue pipe roof clearance.
The top of the flue opening should be at least 10 ft 3 1 m away from any roof surface or other structure.
If you are using a b vent typically a double walled air insulated vent for gas appliances typically you ll see a fire clearance stamped right into the metal of the chimney stating 1 inch minimum clearance to combustibles as you ll see in this photo.
Metal double wall b vent requires 1 inch minimum clearance 3.
Except for flat and very low slope roofs such as those listed in the table below b vents should be at least two feet above the roof surface as well.
Inadequate fire clearance from combustibles may not be obvious until you open a door such as our client is pointing out in this photograph.
Fire clearances required range from 6 to 36 depending on the equipment.
9 is a typical clearance between a gas fired boiler or furnace flue connector and combustibles.
Clearance from combustibles ranging from 0 to 18 to 36 typically depending on the fuel type electric gas oil.
Furnace water heater vent pipe clearance double wall typical listed and labeled double wall vent pipe clearance to combustible materials is one inch but you should always check before installation.
Vent caps 12 and smaller may terminate a distance above the roof if 8 feet or more away from a vertical surface as follows.
Horizontally through the sidewall or vertically through the roof.
See the detailed b vent chimney rooftop clearance table below.
Trim back the wood shift the vent or.
Clearance distances for chimneys that are 10 ft 3 1 m or more away from the roof ridge measured at the up roof side of the chimney.
Transite generally requires 1 to 3 inches depending on various factors.
The 1992 vent sizing tables require that all type b gas vents terminate above the roof with a listed cap or listed roof assembly in accordance with the manufacturer s instructions.
There are several gas or oil fired heating furnace clearance distance types.
In contrast modern high efficiency condensing furnaces exhaust much cooler gasses and need only plastic pipe materials such as pvc cpvc or abs for their exhaust vents some high efficiency furnaces also include a plastic pipe for intake area and all types.
The top of the chimney should be at least two feet above anything within a ten foot radius of the chimney.
The pipes can be set in two ways.
Table of type b vent rooftop clearance requirements.