High efficiency gas furnaces have plastic vent pipes that extend to the outdoors to get rid of exhaust gases and bring in fresh air for combustion.
Furnace pvc exhaust pipe condensation.
Over time the moisture as well as the chemicals released by the furnace can damage the.
Your furnace is designed to collect and drain that condensate.
Without this indoor air will permeate the insulation and condense internally against the pipe.
You don t need to drill any holes in the pipe.
The plastic gas furnace intake pipe can be insulated but any insulation strategy must include a vapour barrier on the outside.
Generally the exhaust pipe should slope back towards the furnace about 1 4 per foot.
It sounds like you have plenty of grade but your pipe is not straight.
Some high efficiency furnaces also include a plastic pipe for intake area and all types use a third plastic pipe to drain away the corrosive condensation resulting from the combustion process.
If the vent pipes are not protected by screens you take a big risk for furnace problems due to pipe obstruction or infestations from pests.
This pipe directs combustible gases away from your home.
This high efficiency venting system must be installed when you install the new furnace.
If your furnace has white pvc exhaust pipes you have a condensing furnace.
Your exhaust pipe is the metal or pvc pipe that connects to your furnace and goes through the roof or side of the house.
These pvc or cpvc pipes can be inviting to rodents and birds especially in the winter as well as insects mostly in summer looking for a home.
High efficiency furnaces produce high amounts of condensation moisture in the exhaust vent which is designed to run back into and through the furnace in order to drain out into either a floor drain or other approved draining system.
In contrast modern high efficiency condensing furnaces exhaust much cooler gasses and need only plastic pipe materials such as pvc cpvc or abs for their exhaust vents.
Your if there was a problem with those exhaust pipes being a source for condensation then codes wouldn t allow a single wall pvc pipe to be in that environment is a declaration that you are making not code.
Other aspects of high efficiency furnace venting.
If your furnace has a metal exhaust pipe you have a conventional furnace.
You will always get condensation in the exhaust flue on a run as long as yours.
The pvc sticks out of the side of the house and the guy who installed the furnace said not to put any screening over the pipe because in very cold weather northern illinois condensation could collect on the screen freeze and seal off the inlet or outlet.
Condensation in the flue or vent pipe is not dangerous in itself but can create a dangerous condition.